Why do some models have two input voltages, VLOW and VHIGH?

The pulser connects VHIGH (the +HV power supply) to the output when the input is high, and connects VLOW (the –HV power supply) to the output when the input is low. The two input voltages allow the output to rest at a DC level between pulses.